OT Light
Illumination Intensity: 40,000 to 160,000 Lux
Light Source: LED or Halogen technology
Color Temperature: 4,000K to 5,500K (daylight range)
Diameter of Light Head: 500 mm to 700 mm (approx.)
Depth of Illumination: ≥ 600 mm for shadowless effect
Power Supply: AC 220V ±10%, 50/60 Hz
Battery Backup: Optional in advanced models (30–60 mins)

Ventilator
Tidal Volume: 50 – 1500 mL
Respiratory Rate: 2 – 60 breaths per minute
FiO₂ (Oxygen Concentration): 21% – 100%
PEEP (Positive End-Expiratory Pressure): 0 – 20 cmH₂O
I:E Ratio: Adjustable (e.g., 1:1 to 1:4)
Ventilation Modes: Volume Control, Pressure Control, SIMV, CPAP, BiPAP
- Display: LCD/LED showing parameters (PIP, Tidal Volume, RR, FiO₂)
Power Supply: AC 220V ±10%, 50Hz + internal battery backup (30–120 min)

X-ray
Tube Voltage (kVp): 40 – 125 kVp
Tube Current (mA): 50 – 500 mA
Exposure Time: 0.001 – 6 seconds (adjustable)
Power Output: 100 – 500 mA X-Ray generator
Focus Size: 0.6 mm – 1.5 mm for image clarity
Image Receptor: Film, CR (Computed Radiography)
Control Console: Digital or Analog with timer and display
Power Supply: 220V ±10%, 50/60 Hz

Anaesthesia Machine
Gas Sources: Oxygen, Nitrous Oxide, and Medical Air connections
Flowmeters: Precise dual/triple flowmeters for gas control
Vaporizers: Calibrated vaporizers for agents like Isoflurane, Sevoflurane
Breathing System: Circle breathing system with CO₂ absorber
Ventilator: Integrated ventilator with adjustable settings
Safety Features: Hypoxia prevention, oxygen failure alarm, pressure relief valves
Power Supply: AC 220V ±10%, 50/60 Hz with backup options

Oxygen Concentator
Oxygen Concentration: 90% ± 3% at 1–5 L/min flow rate
Flow Rate: Adjustable from 1 to 5 L/min (some models up to 10 L/min)
Outlet Pressure: 5 – 10 psi (34 – 70 kPa)
Sound Level: ≤ 50 dB (low noise design)
Power Supply: AC 220V ±10%, 50 Hz
Power Consumption: 300 – 600 Watts depending on capacity
Safety Features: Overheat protection, Low oxygen purity alarm, Power failure alarm

ICU Bad
Frame Material: High-strength steel with anti-corrosive coating
Sections: 4 or 5-section design for multiple patient positions
Position Adjustments: Head, leg, Trendelenburg & Reverse Trendelenburg positions
Height Adjustment: Motorized or manual (typically 450 mm – 750 mm)
Mattress Platform: ABS or perforated metal for ventilation
Side Rails: Collapsible/ABS safety side rails for patient protection
Casters: 125 mm or 150 mm with central locking and steering control

Autoclave Machine
Type: Vertical, Horizontal, or Table-top (depending on application)
Capacity: Common sizes range from 10 liters to 100 liters
Sterilization Temperature: 121°C – 134°C
Pressure Range: 15 – 30 psi for effective sterilization
Material: Stainless steel chamber with anti-corrosion coating
Power Supply: 220V ±10%, 50/60 Hz, single-phase or three-phase
Safety Features: Automatic pressure control, safety valve, low water level cut-off

ECG Machines
Channel configuration: available in 1-channel, 3-channel, 6-channel, and 12-channel models
Display: LCD / LED screen for waveform and patient details
Recording system: Thermal printer with standard ECG paper
Filters: AC filter, EMG filter, baseline drift filter to reduce noise
Patient safety: Isolated input, defibrillator protection
Connectivity: USB / LAN / Bluetooth (in advanced models) for data transfer
Power supply: Works on AC mains and rechargeable battery

Co2 Insufflation
Flow rate adjustable from low to high (around 1–40 L/min)
Pressure range suitable for surgery (about 1–30 mmHg)
Clear digital display showing pressure, flow, and volume
Built-in safety alarms for overpressure and low pressure
Works with CO₂ gas cylinder or central supply
Separate modes for adult and pediatric patients
Supplied with tubing and standard connectors